How to restart a Gaussian Run


 Using Gaussian Checkpoint Files

Since the new queue structure on scientific servers have time limits, the Gaussian calculations may be terminated prematurely due to inadequate length of time. To restart such a prematurely terminated calculation, one can use the check pointing facilitated via the Gaussian supported checkpointing file. However, note here that the primary use of a checkpoint file is to use the results of one calculation as the starting point for a second calculation.

When a Gaussian calculation is restarted using information from a checkpoint file, the new calculation results (or the continuation from the uncompleted run) will be placed in the exact same checkpoint file, overwriting the original checkpoint file. THUS IT IS ALWAYS SAFER TO MAKE A BACKUP COPY OF THE CHECKPOINT FILE. Note that it is possible for a checkpoint file to become corrupted (i.e. if a calculation dies while writing to the checkpoint file).

Gaussian will use a checkpoint file if the command:

    %Chk=file_name

appears before the route card in the input file. If the specified file does not exist, it will be created. If the specified file does exist, information to be used in the present calculation can be read from it.

 Commands for reading from the checkpoint file

A calculation can be started using information from the checkpoint file by including one of the following commands in the route card.

ChkBasis

Read the basis set from the checkpoint file.

SCF=Restart

Restart an SCF calculation from the checkpoint file. This is normally used when an SCF calculation failed finish for some reason.

IRC=Restart

Restarts an IRC calculation that did not complete, or restarts an IRC calculation for which additional points along the reaction path are desired.

Scan=Restart

Restarts a potential energy surface scan which did not complete.

Freq=Restart

Restarts a numerical frequency calculation which did not complete. Analytic frequency calculations cannot be restarted.

Polar=Restart

Restarts a numerical polarizability calculation which did not complete.

CIS=Restart

Restarts a CIS (Configuration Interaction - Single excitation) calculation which did not complete.

Opt=Restart

Restarts an geometry optimization which did not complete.

Geom=Checkpoint

Reads the molecular geometry from the checkpoint file.

Geom=AllCheckpoint

Reads the molecular geometry, charge, multiplicity and title from the checkpoint file. This is often used to start a second calculation at a different level of theory.

Guess=Read

Reads the initial guess from the checkpoint file. If the basis set specified is different from the basis set used in the job which generated the checkpoint file, then the wave function will be projected from one basis to the other. This is an efficient way to switch from one basis to another.

Density=Checkpoint

Reads the density from the checkpoint file. This inplies Guess=Only so that no integrals or SCF are computed. This is used to compute the population analysis or create cube files from a wave function without rerunning the job.

Field=Checkpoint

Reads the 34 multipole components of a finite field from the checkpoint file.

Field=EChk

Reads the 3 electric dipole field components from the checkpoint file.

Charge=Check

Reads point charges from the checkpoint file.

ReArchive

This option is used to generate an archive entry from the information in the checkpoint file. No calculation is run.

Copyright 2002-2007 The University of North Carolina at Chapel Hill.

Creative Commons License
This work is licensed under a Creative Commons Attribution 3.0 United States License.

Post a Comment

This form is for document feedback. If you need technical assistance, and are affiliated with UNC-Chapel Hill, please Submit a Help Request
Optional
Optional
So that we may contact you.
Do not fill out this form, this is a spam trap.
Top
University of North Carolina - Chapel Hill